Informativity Institute · Research brief · 2 November 2026

Shared calibration and fundamental reference uncertainties

A coherent length, mass and time calculation, its common input dependence and the consequences for products, ratios and evidence.

Recorded source version: October 13, 2026 · Brief prepared: November 2, 2026
Read the companion press release

What the reference set contributes

The research milestone is a reproducible set of dimensional MQ references with a coherent input ledger. Different manuscripts can then evaluate their dependent quantities without mixing input editions or treating repeated calibration information as independent evidence. The same central values can support a correct or an incorrect uncertainty budget depending on whether their shared dependence is retained. [1] [2]

MQ begins from discrete measure and derives count relationships with a proposed physical realization. The Internal Frame describes count configurations; the System Frame expresses realized measures through the Frames mapping. Deriving the form of a relationship, selecting a coefficient corresponding to our universe and assigning dimensional reference units have distinct roles. The numerical profile here fixes the latter choices while retaining the source’s count premises. [1] [2]

Quantities and the defining reference relations

Let 𝑙𝑓, 𝑚𝑓 and 𝑡𝑓 denote fundamental length, mass and time, in m, kg and s. Let 𝑐 denote vacuum light speed, exactly 299792458 m s⁻¹ in the SI. Let 𝜃𝑠𝑖 be the dimensionless MQ coefficient, and 𝑝𝑠𝑖 its momentum realization in kg m s⁻¹. The source’s adopted SI normalization assigns the latter the same numerical coefficient, 3.26239030504(25), without identifying the two dimensions. Equation (1a) uses the dimensional momentum quantity. [1] [2] [3]

𝑚𝑓=2𝑝𝑠𝑖𝑐(1a)

Let 𝑚𝑒 be electron mass in kg, 𝑎0 the Bohr radius in m and 𝛼𝑝 the dimensionless Planck-like fine-structure coupling. Equation (2b) gives the source’s orbital length relation. Its numerator has units kg m and division by fundamental mass gives metres. The reference set does not assign momentum units to the dimensionless coefficient to repair this equation. [1] [2]

𝑙𝑓=𝑚𝑒𝑎0𝛼𝑝𝑚𝑓(2b)

The time reference follows from length and the exact speed input in Equation (3c). Thus length and time share their entire relative calibration dependence in this profile. The local equation labels in this Brief are distinct from the source’s labels; the reference calculation appears in Eqs. (26)–(30) of the fundamental-measures manuscript. [1]

𝑡𝑓=𝑙𝑓𝑐(3c)

Figure 1 follows the common input into the coefficient, its specified dimensional realization and the three references. A branching calculation diagram does not mean each branch carries a separate experiment. Exact SI anchors and fixed prescriptions remain part of the calculation even when they add no propagated input uncertainty. [1] [2]

A common calibration feeds three fundamental referencesThe 2022 inverse fine-structure input selects a coefficient and a specified momentum realization. The length, mass and time references share this input and must be propagated coherently. Exact SI anchors and fixed realization premises are distinct inputs. One calibration, three linked references 2022 INVERSE FINE-STRUCTURE INPUT137.035999177(21) COEFFICIENT AND REALIZATIONDimensionless coefficient; specified SI momentum mappingExact SI anchors and a fixed source count branch LENGTHCalculated in metresFalls as calibration input rises MASSCalculated in kilogramsRises as calibration input rises TIMELength divided by exact light speedFalls with the length reference PROPAGATE THE COMMON INPUTProducts and ratios retain the shared dependence These are calculation dependencies, not three independent measurements.
Figure 1. Redrawn dependency map of the current source profile. Length and time move together under the selected input variation; mass moves oppositely. The diagram describes a calculation, not an apparatus or a microscopic image.

Reduce the orbital product before propagating uncertainty

Let 𝛼𝑐–1 denote the dimensionless classical inverse fine-structure input, 137.035999177(21). Let ħ denote the conventional reduced Planck constant used for calibration, in J s. Its SI value is exact through the defining Planck constant divided by twice the circle constant. This conventional input must be distinguished from the different MQ upper-count action output. Equation (4d) is the conventional orbital identity used in the current source. [1] [2] [3] [5]

𝑚𝑒𝑎0=ħ𝛼𝑐–1𝑐(4d)

Substituting Equation (4d) into Equation (2b) removes electron mass and Bohr radius as separate adjusted inputs to this numerical profile. Multiplying their individually rounded recommendations and adding their uncertainties as if independent would discard their adjustment dependence. The symbolic appearance of two quantities does not itself identify two independent sources of uncertainty. [1] [2]

The calibrated Planck-like coupling and momentum are also functions of the same inverse fine-structure input. The source uses the fixed nearest-whole-unit branch 137 in its coefficient inversion. That branch stays unchanged across the stated input interval. Propagation must rerun the complete dependent sequence; holding a downstream quantity fixed while varying its parent would define a different calculation. [1] [2]

Table 1: The coherent input ledger and its distinct roles
Input or prescriptionValue or treatmentRole
Classical inverse fine-structure input137.035999177(21)One adjusted uncertain selector
Vacuum light speed299792458 m s⁻¹Exact SI numerical anchor
Planck constant6.62607015 × 10⁻³⁴ J sExact SI numerical anchor
Electron mass × Bohr radiusReduced with Equation (4d)No extra independent adjusted input
Coefficient and momentum realizationSame numerical coefficient; different dimensionsSpecified realization normalization
Count branch and MQ relationsHeld fixed through the input shiftsConditional construction premises

Table 1 distinguishes the input’s role from the law’s form. A measured selector is not automatically the axiom from which the relationship was derived. Its uncertainty still enters numerical outputs, and the adopted normalization is not an independent momentum measurement. That separation is central to interpreting the claimed precision. [1] [2]

Reproduced references and their signed response

The calculation used 90-digit arithmetic and repeated the fixed-branch sequence at the input shifted up and down by its stated standard uncertainty of 0.000000021. Half the difference between those outputs supplies the local propagated input uncertainty. Displayed values are rounded only after calculation. Parentheses in Table 2 indicate standard uncertainty in the last displayed digits. [1] [2]

Table 2: Calculated references and response to the shared input
ReferenceSI value with conditional uncertaintyFractional response to one positive input uncertainty shift
Fundamental length1.61619991148(12)×10−35m−7.66416 × 10⁻¹¹
Fundamental mass2.17643254057(17)×10−8kg+7.66363 × 10⁻¹¹
Fundamental time5.39106261131(41)×10−44s−7.66416 × 10⁻¹¹

Table 2’s responses are local, rounded sensitivities for the one-input profile. The signs matter. Length and time decrease together while mass increases. In the first-order covariance description this produces a rank-one uncertainty matrix, positive correlation for length with time and negative correlations for mass with either. Those first-order correlations describe calibration propagation, not a separately measured joint distribution of microscopic lengths and masses. [1] [2]

The absolute standard uncertainties are about 1.23868 × 10⁻⁴⁵ m, 1.66794 × 10⁻¹⁸ kg and 4.13180 × 10⁻⁵⁴ s, respectively. Printing those small errors does not establish experimental access at those scales. The intervals omit uncertainty in the count premises and physical realization prescriptions. [1] [2]

Exact identities explain cancellation and residual dependence

The fundamental relation in Equation (5e) follows directly by multiplying Equation (1a) by length and using Equation (3c). It is an algebraic relationship within the same calibrated reference set, not a fourth independent measurement. [1] [8]

𝑙𝑓𝑚𝑓=2𝑝𝑠𝑖𝑡𝑓(5e)

Combining Equations (2b) and (4d) gives Equation (6f). The length–mass product therefore retains the source dependence of the two coupling quantities. Their nearly compensating changes leave a small nonzero uncertainty. The fact that the reduced Planck input and light speed are exact does not make that product exact. [1] [2]

𝑙𝑓𝑚𝑓=ħ𝛼𝑐–1𝛼𝑝𝑐(6f)

Worked products and ratios

Table 3 and Figure 2 recompute three combinations using the same shifted input. The contrasting column deliberately discards covariance and combines the individual relative uncertainties in quadrature. It is shown as an error demonstration, not as an alternative valid budget for this source profile. [1] [2]

Table 3: Shared-input propagation compared with incorrectly imposed independence
CombinationCorrect relative standard uncertaintyIncorrect independent-input result
Length / time0 within the defining identity1.08388 × 10⁻¹⁰
Length × mass5.35319 × 10⁻¹⁵1.08384 × 10⁻¹⁰
Mass / length1.53278 × 10⁻¹⁰1.08384 × 10⁻¹⁰

Length divided by time returns 299792458 m s⁻¹ exactly under Equation (3c). Assigning independent errors to numerator and denominator creates a spurious uncertainty on this input recovery. This cancellation is a property of the defining calculation. A laboratory speed determination has its own realization effects and uncertainty. [1] [3] [5]

The length–mass product is 3.51755007940 × 10⁻⁴³ kg m at the central profile. Its relative input uncertainty is much smaller than the individual reference uncertainties because their dominant variations oppose one another. It is not zero, as Equation (6f) shows. By contrast, in mass divided by length those opposite shifts add, so ignoring their dependence understates the uncertainty. Shared input does not always mean a smaller final error. [1] [2]

2026-11-02T17:14:47.634048 image/svg+xml Matplotlib v3.11.2, https://matplotlib.org/ 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 Relative standard uncertainty, in units of 10⁻¹⁰ Length / time Length × mass Mass / length 0 (identity) 5.353e-15 1.533e-10 1.084e-10 1.084e-10 1.084e-10 The same reference uncertainties combine differently One calibrated input · fixed realization and count branch · input-only propagation Bar labels give dimensionless relative uncertainties. A zero here does not mean a perfect laboratory realization. Shared input retained Independence incorrectly imposed
Figure 2. Computed relative standard uncertainties from the coherent source profile and from the deliberately incorrect independence assumption. The zero is an exact input-recovery identity. The small product uncertainty is labeled numerically because its bar is too short to resolve on this linear scale.

For a general measurement model, the GUM’s propagation framework retains covariance between correlated inputs. Here the complete one-input recalculation already carries that dependence. Additional uncertain inputs would require their joint information and sensitivities; the rank-one description would no longer be sufficient merely because it worked for the present profile. [4]

What the reported uncertainty includes

The reported uncertainties include sensitivity to the specified fine-structure calibration with exact SI anchors and source prescriptions fixed. They do not include a quantified discrepancy between the physical world and the proposed realization map. That missing contribution has not been measured to be zero. Narrow conditional intervals therefore cannot be read as a complete statement of physical accuracy. [1] [2]

Other calculations can add independent observational inputs, such as a measured temperature or an apparatus quantity. Those inputs need their own uncertainty and any cross-dependence. The current three-reference budget must not be carried into an extended model as if it already included all such sources. Conversely, reintroducing electron mass and Bohr radius as independent uncertainties after the orbital reduction would count the adjustment information incorrectly. [1] [2]

The constants manuscript also examines a separate rubidium-recoil fine-structure input as a source-sensitivity exercise. It reruns the chain with that source and its uncertainty. That comparison is not a new authoritative calibration here, and the two columns are not assumed statistically independent. Changing input editions or experiments requires updating the entire dependent set, not selecting favorable rows from different versions. [2]

What consistency establishes and what requires a test

Recovering an input or satisfying the fundamental relation checks the implementation of the stated dependencies. Reproducing the same reference set in the Planck-root construction provides another algebraic representation under compatible upper-count quantities. Neither operation adds an independent measurement or proves the physical discreteness of measure. Conventional Planck units and their metrological uncertainty budget retain their separate definitions. [1] [8]

An independent test must specify a physical observable, its realized apparatus or astronomical model, the frozen calibration and premises, and data that add information beyond the input already used. Comparisons across derived constants need the complete covariance of predictions and references, including shared information. A collection of related residuals cannot be multiplied into a global significance as if each were a separate experiment. [1] [2] [10]

The bounded-domain discussion linked from the original release concerns the admitted count domain. It is useful theoretical context, but it supplies neither a laboratory determination of these references nor an uncertainty budget for practical measurement at their scales. [9]

Chronology and reporting guidance

October 13, 2026 is the recorded source-version date for this retrospective archive. It is not established here as the first discovery, original announcement or journal publication date. This Brief was prepared November 2, 2026 against the current public technical sources. Journal publication of those current versions is not established. [1] [2] [8] [9]

For interviews, request the unrounded reference set, source edition, branch prescription and coherent input ledger. Ask which quantities select the numerical realization and which relations derive its form. Preserve the distinction between source-input uncertainty, practical realization uncertainty and model discrepancy. A complete story should report both the reproducibility achievement and the independent physical tests still needed.

Research sources and further reading

  1. J. A. Geiger, Fundamental Measures of Measurement Quantization. Current public preprint, calibration Eqs. (18)–(31), particularly Eqs. (26)–(30), and comparison discussion. Uses one coherent reference set. Journal publication of this version is not established. Open source →
  2. J. A. Geiger, Extending Precision of the Physical Constants. Current public manuscript, Introduction, Methods, Sections 3.1–3.3 and Table 3. Fixed 2022 calibration, orbital-product reduction and shared dependencies. Journal publication of this version is not established. Open source →
  3. NIST, Fundamental Physical Constants, complete listing, 2022 CODATA adjustment. Inverse fine-structure input and exact SI anchors. The MQ reference calculations are not CODATA recommendations. Open source →
  4. JCGM 100:2008, Evaluation of measurement data — Guide to the expression of uncertainty in measurement, Sections 5.1–5.2. General framework for propagating uncertain inputs with correlations. This guidance does not validate MQ realization premises. Open source →
  5. BIPM, 26th CGPM Resolution 1 (2018), effective May 20, 2019. Exact SI defining values for Planck’s constant and vacuum light speed. Exact definitions do not eliminate uncertainty in practical realizations. Open source →
  6. Informativity Institute, Inputs. Overview of recurring physical quantities. For the present numerical evaluation, the current technical manuscripts reduce the electron-mass–Bohr-radius product before propagation. Open source →
  7. Informativity Institute, Concordance and Consistency Analysis for Measurement Quantization. Related comparison overview; algebraic consistency and shared calibration are distinct from independent experimental validation. Open source →
  8. J. A. Geiger, Deriving the Planck Unit Expressions. Current public preprint. Compatible upper-count quantities recover the same MQ measures; conventional Planck inputs retain separate roles. Journal publication of this version is not established. Open source →
  9. J. A. Geiger, Singularity Exclusion in the Bounded Measurement Quantization Domain. Related source on count-domain restrictions; not an independent measurement of the calibrated references. Journal publication of this version is not established. Open source →
  10. Informativity Institute, Predictions of Measurement Quantization. Evidence and independent-test context. Open source →

Prepared November 2, 2026. Source equations, dimensions, numerical reference values and common-input combinations checked. Graphics explain the calculation and do not depict measured microscopic structure.

Return to the press release