Informativity Institute · Research brief · 2 November 2026

Magnetic permeability and shared dependencies

The exact electric-to-magnetic link, the current MQ numerical route and the covariance that prevents double-counting evidence.

Recorded source version: October 13, 2026 · Brief prepared: November 2, 2026
Read the companion press release

The exact dependency comes first

Let 𝜇0 be vacuum magnetic permeability in H m⁻¹, ɛ0 vacuum electric permittivity in F m⁻¹ and 𝑐 vacuum light speed in m s⁻¹. In the present SI, light speed is exactly 299792458 m s⁻¹. Equation (1a) is the conventional identity retained by the MQ calculation. [1] [4] [5]

𝜇0=1ɛ0𝑐2(1a)

Thus a specified electric result fixes the magnetic result at exact light speed. Physically distinct electromagnetic roles do not imply independent numerical information. The SI revision effective May 20, 2019 fixed elementary charge and Planck’s constant; permeability ceased to have its former exact assigned value. Its recommended value now depends on measured fine-structure information. “Exact identity” and “exact numerical permeability” are different claims. [4] [5]

What the current forward MQ route supplies

The current constants manuscript constructs the electric output through a forward count-and-charge realization and fundamental gamma. This differs from a historical auxiliary electromagnetic parameter resolved using measured constants. The forward route removes those electric and magnetic values as direct numerical inputs, but retains the inverse fine-structure calibration, exact SI references and the count, momentum and charge-realization conventions. [1] [2] [3]

The fundamental physical references are 𝑙𝑓 in metres, 𝑚𝑓 in kilograms and 𝑡𝑓 in seconds. The momentum realization 𝑝𝑠𝑖 has units kg m s⁻¹. Normalized fundamental gamma γ𝐹 is dimensionless; its mapped physical realization 𝛾𝐹,sys has units C². The latter is used in the dimensional expressions below and is not a separately fitted parameter. Let π denote the upright dimensionless circle constant. [1] [2]

ɛ0=4𝛾𝐹,sysπ𝑙𝑓𝑚𝑓𝑐2(2b)

Substituting Equation (2b) into Equation (1a) cancels the light-speed square and yields the first expression in Equation (3c). The source’s dimensional fundamental relation equates fundamental length times fundamental mass to twice momentum times fundamental time, giving the second expression. A dimensionless coefficient cannot replace the dimensional momentum merely because an adopted SI numerical coordinate happens to coincide. [1] [2]

𝜇0=π𝑙𝑓𝑚𝑓4𝛾𝐹,sys=π𝑝𝑠𝑖𝑡𝑓2𝛾𝐹,sys(3c)

Both numerator forms in Equation (3c) have units kg m; dividing by C² gives H m⁻¹. The Internal Frame is the dimensionless count-configuration domain. Physical measures and charge-squared gamma belong to the System Frame realization through the Frames mapping. Giving the configuration gamma physical charge units would conflate these roles. [1] [2]

Shared calibration and linked electromagnetic outputsThe inverse fine-structure calibration and exact SI references feed a forward count and charge route, which yields electric permittivity. Exact reciprocal identities then give magnetic permeability and Coulomb coupling. Multiple outputs are not independent experiments. image/svg+xml Matplotlib v3.11.2, https://matplotlib.org/ Shared calibration Inverse fine structure Exact SI references Forward MQ route Count and charge realization Fundamental references Electric output Vacuum permittivity Linked outputs Vacuum permeability Coulomb coupling No measured permittivity or permeability is inserted as a direct input to this forward gamma route. The upstream calibration still remains. One dependency chain produces several electromagnetic rows The exact reciprocal links do not create additional independent measurements.
Figure 1. Redrawn dependency map of the forward route. The electric output and its linked magnetic and Coulomb quantities retain their calibration and realization premises. Separate output boxes are not separate experimental inputs or confirmations.

Reproduce the current numerical family

Table 1 identifies the retained calibration. A 90-digit fixed-branch evaluation reproduced the forward count, charge and gamma route and reran it at the common inverse fine-structure input shifted by its standard uncertainty. The quoted conditional sensitivities retain that one shared uncertain input. They do not include uncertainty in the physical realization convention or model discrepancy. [2] [4]

Table 1: Calibration and dependency roles retained in the recalculation
Quantity or choiceValue or roleStatus
Inverse fine-structure input137.035999177(21)Uncertain 2022 adjustment input
Vacuum light speed299792458 m s⁻¹Exact SI reference
Planck constant6.62607015 × 10⁻³⁴ J sExact SI reference
Count branch and SI realizationFixed as in the forward source calculationModel and representation premises
Permittivity and permeabilityCalculated downstreamNot direct measured inputs to this route
Table 2: Reproduced forward outputs and the separately recommended reference; parentheses give conditional standard uncertainty in final digits
QuantityValueInterpretation
MQ electric output8.8541878035(20)×10−12F m⁻¹Forward calculated value
MQ magnetic output1.25663706345(28)×10−6H m⁻¹Exact reciprocal of the electric output
MQ Coulomb output8.9875518017(20)×109N m² C⁻²Linked electromagnetic output
MQ physical gamma2.19846879611(49)×10−37C²Derived charge-squared realization
2022 CODATA permeability1.25663706127(20)×10−6H m⁻¹Recommended metrological reference, not an MQ measurement

Table 2’s MQ permeability exceeds the printed CODATA reference by about 2.1752 × 10⁻¹⁵ H m⁻¹. That difference is a numerical residual, not a complete statistical significance. The two descriptions share metrological information and need a cross-covariance treatment; the MQ model discrepancy is unquantified. The forward route is also distinct from the source’s separate exact-charge inversion, which recovers a defining input by construction. [1] [2] [4]

The public magnetic page contains mixed numerical versions. Its current figure gives the reproduced value in Table 2, while older prose retains 1.2566370635(18) × 10⁻⁶ H m⁻¹ and a 1.93σ comparison. This Brief does not merge those uncertainties or reuse that quoted significance. The updated figure and current forward calculation control the displayed numerical ledger. [1] [2]

Why the product has no propagated input uncertainty

Multiplying Equation (1a) by its denominator gives Equation (4d). This identity is satisfied for every positive electric input at fixed light speed. Recovering it therefore checks algebraic closure, not the physical accuracy of the electric prediction. [1] [3]

𝜇0ɛ0𝑐2=1(4d)

The common-input relative standard uncertainty is about 2.2152 × 10⁻¹⁰ in each of the MQ electric and magnetic outputs. If those propagated errors were falsely treated as independent, the relative uncertainty assigned to Equation (4d)’s product would be about 3.1328 × 10⁻¹⁰. With the dependency retained, the product is exactly constant and its input-propagated uncertainty is zero. This cancellation does not assign zero uncertainty to the model’s physical premises. [2] [6]

Reciprocal sensitivity and covariance

At fixed light speed, differentiating Equation (1a) gives Equation (5e). The derivative is exact. Its use in ordinary first-order uncertainty propagation is a linearized calculation; that propagation order should not be confused with an exact finite-variation formula. [6]

∂𝜇0∂ɛ0=−1𝑐2ɛ02=−𝜇0ɛ0(5e)

The electric and magnetic perturbations have opposite signs. Their first-order relative standard uncertainties have the same magnitude, and their first-order covariance is negative: multiply the electric variance by the negative magnetic-to-electric ratio. Under this single-input linearization, their correlation is minus one. This is a statement about the propagated model, not a measured statistical correlation of independent apparatus results. [6]

Deterministic reciprocal responseAt fixed light speed, a decrease in permittivity increases the linked magnetic and Coulomb outputs. A one-percent decrease gives about one point zero one zero one percent increase. The plotted variations are examples, not measured errors. image/svg+xml Matplotlib v3.11.2, https://matplotlib.org/ −1.00 −0.75 −0.50 −0.25 0.00 0.25 0.50 0.75 1.00 Selected permittivity change (%) −1.00 −0.75 −0.50 −0.25 0.00 0.25 0.50 0.75 1.00 Linked output change (%) Magnetic and Coulomb output change First-order tangent at zero Reciprocal propagation reverses the electric change Exact inverse response at fixed light speed; a 1% example is deliberately much larger than the quoted uncertainty. Deterministic sensitivity illustration, not data, a confidence band or an independent experimental test.
Figure 2. Deterministic reciprocal sensitivity at fixed light speed. A selected 1% electric decrease produces a 1.010101% linked increase; a 1% electric increase produces a 0.990099% linked decrease. The tangent describes the first-order sensitivity. These deliberately large variations are illustrative, not uncertainty intervals or observations.

Figure 2 shows why the exact finite response is not a symmetric percentage rule, even though its tangent reverses equal relative changes at first order. The propagated uncertainty here is many orders of magnitude smaller than the selected 1% illustration. If several genuinely uncertain inputs were used, their full covariance would have to be propagated before assessing the outputs. [6]

The Coulomb row carries the same electric information

Let 𝑘𝑒 be Coulomb coupling in N m² C⁻². Its conventional reciprocal relation to permittivity, combined with Equation (1a), gives Equation (6f). Magnetic permeability and Coulomb coupling are exact positive multiples of one another when light speed is fixed. [1] [2] [3]

𝑘𝑒=14πɛ0=𝜇0𝑐24π(6f)
Table 3: Dependence and evidence in the linked electromagnetic family
Comparison or transformationCorrect treatmentMisinterpretation to avoid
Electric and magnetic propagated errorsOpposite first-order signs; retain their covarianceIndependent electric and magnetic error bars
Magnetic and Coulomb outputsExact positive scaling at fixed light speedTwo independent electromagnetic tests
Permeability × permittivity × light speed squaredExactly one; input dependencies cancelNonzero uncertainty from independent-row quadrature
MQ and CODATA residualJoint source dependencies and model assumptions neededA standalone significance from a quoted sigma
Current forward route and exact-charge inversionKeep the input directions separateInput recovery presented as a new prediction

Table 3 explains why physically different constants can supply only one inherited direction of numerical variation in this calculation. The first-order output covariance is rank one when a single uncertain input drives the nonconstant outputs. Replicating the same information in several parameterizations does not multiply the amount of independent evidence. [2] [6]

What an independent test would require

A prospective test needs a defined observable, an independently justified source and uncertainty chain, and an apparatus model that connects the proposed realization to the recorded signal. A conventional magnetic-field illustration or a numerical permeability row does not supply that measurement. Reusing the same electromagnetic adjustment or recovering an exact SI input must be disclosed. [1] [7]

A useful analysis should freeze the count branch and realization convention, state all direct inputs and report their covariance. It should distinguish source-input uncertainty, numerical precision, metrological cross-dependence and physical model discrepancy. An agreement claim remains conditional until those distinct contributions are addressed. [2] [4] [6]

Chronology and source requests

October 13, 2026 is the recorded source-version date used in this retrospective archive, not an established original discovery, announcement or journal publication date. This Brief was prepared November 2, 2026 using the current public figure and forward constants calculation. Journal publication of these current MQ manuscript versions is not established. [1] [2]

For an interview, request the versioned numerical ledger and joint covariance before comparing uncertainties or counting confirmations. Ask which magnetic observable is predicted independently of the electric calibration. The result delivered here is a reproducible linked calculation with retained dependencies, not a new measurement of vacuum permeability.

Research sources and further reading

  1. J. A. Geiger, Describing the Magnetic Constant Using Only the Fundamental Measures. Current public magnetic-constant manuscript and its updated opening figure. The figure uses dimensional momentum, charge-squared gamma realization and 1.25663706345(28) × 10⁻⁶ H m⁻¹. Older prose on the same page retains a different quoted uncertainty and a 1.93σ comparison; those are not substituted for the current calculation here. Journal publication of this version is not established. Open source →
  2. J. A. Geiger, Extending Precision of the Physical Constants. Current technical manuscript, forward count-and-charge route, fundamental gamma, SI realization and electromagnetic outputs. The separate exact-charge inversion is not the forward calculation used in this Brief. Journal publication of this version is not established. Open source →
  3. Informativity Institute, Electric Constant from First Principles. Public technical manuscript and current figure; supplies the electric output and its electromagnetic dependency context. Open source →
  4. NIST, Fundamental Physical Constants, complete listing, 2022 CODATA adjustment. Reference permeability, permittivity, fine-structure input and exact SI defining constants. Recommended adjusted values are not separate MQ experiments. Open source →
  5. BIPM, 26th CGPM Resolution 1 (2018), effective May 20, 2019. Fixes the defining constants and explains that vacuum permeability is subsequently determined experimentally rather than assigned its former exact numerical value. Open source →
  6. JCGM 100:2008, Evaluation of measurement data — Guide to the expression of uncertainty in measurement. Section 5.2 addresses correlated input quantities. The linearized covariance calculation is a propagation model, not a complete assessment of theory discrepancy. Open source →
  7. Informativity Institute, Predictions of Measurement Quantization. Evidence and independent-test context. Multiple algebraically linked outputs do not constitute multiple independent validations. Open source →
  8. Informativity Institute, Magnetic Constant in Measurement Quantization. Related explanation; read its older coefficient and gamma wording alongside the updated dimensional representations in source [1] and the forward calculation in source [2]. Open source →

Prepared November 2, 2026. Forward numerical family, dimensional identities, reciprocal sensitivities and shared-input cancellation checked. No independent permeability experiment or complete discrepancy significance is claimed.

Return to the press release