Informativity Institute · Research brief · 26 October 2026

The NIST torsion-balance mode comparison

The experimental values and covariance, the fixed MQ target, reproduced mode contrasts and the distinction between compatibility and causal identification.

Experiment published: April 16, 2026 · Archive review snapshot: September 27, 2026 · Brief prepared: October 26, 2026
Read the companion press release

Which experimental record controls

The primary source is Schlamminger and collaborators’ Redetermination of the gravitational constant with the BIPM torsion balance at NIST, Metrologia 63, 025012, DOI 10.1088/1681-7575/ae570f. The paper prints publication on April 16, 2026. It reports a combined estimate of 6.67387 ± 0.00038, multiplied by 10⁻¹¹ m³ kg⁻¹ s⁻², with relative standard uncertainty about 57 ppm. [1]

The NIST publication-metadata abstract displays a different numerical result. The paper itself, including its results tables and consensus treatment, governs this Brief. The combined estimate is not a mode gap or an independent fifth configuration. Its uncertainty reflects the consensus procedure rather than a simple reading of one primary mode budget. [1] [2]

What the two operating modes do

A torsion balance detects the torque generated by source masses acting on suspended test masses. In the free-deflection or Cavendish method, the pendulum moves and its angular response supplies the mechanical signal. In electrostatic-servo operation, feedback applies a balancing electrical torque to keep the angle fixed. Figure 1 shows these functions, rather than an engineering drawing of the actual apparatus. [3]

Both methods retain the gravitational interaction and their own calibration chain. Free operation is not devoid of electrical metrology, and servo operation does not replace gravity with an electromagnetic force between the source and test masses. The proposed MQ association concerns how the measured torque is realized and read out; it is an additional interpretation. [3] [4]

Figure 1. Two operating procedures for the gravitational torqueFree deflection reads the pendulum angular response. Electrostatic servo holds the angle with a balancing torque. Both retain the gravitational source interaction. The diagram is conceptual, not to scale, and does not prove an MQ realization assignment.Different readout procedures, the same gravitational source interaction Free deflection / Cavendish Electrostatic servo Read angular responseMechanical torque inferenceElectrostatic feedbackHold angle with balancing torqueConceptual illustration · not to scale · no realization assignment is proved by the drawing
Figure 1. Functional illustration based on [1] and [3]. It is not a photograph, dimensioned NIST layout or depiction of an already verified MQ mechanism.

The four values and the covariance

Table 1 transcribes the mode central values from the paper’s Table 16 and the more detailed combined relative standard uncertainties from Tables 17–18. The uncertainty values include the stated primary contributions, rather than Type A statistical uncertainty alone. The common unit multiplier applies to each central value. [1]

Table 1: Published primary mode inputs for the reconstructed contrasts
ConfigurationGravitational constant (10⁻¹¹ m³ kg⁻¹ s⁻²)Relative standard uncertainty (ppm)
Copper servo6.67364223.2
Copper free deflection6.67402130.3
Sapphire servo6.67263737.5
Sapphire free deflection6.67363693.9

The modes share input quantities, so their errors are correlated. Table 2 reproduces the six off-diagonal correlation coefficients from the paper’s Table 18 and supplies the unit diagonal appropriate to a correlation matrix. In the source table the diagonal instead prints relative standard uncertainties; those values are kept separately in Table 1 here. [1]

Table 2: Correlation matrix reconstructed from the paper’s Table 18
ConfigurationCopper servoCopper freeSapphire servoSapphire free
Copper servo10.420.380.12
Copper free deflection0.4210.230.23
Sapphire servo0.380.2310.25
Sapphire free deflection0.120.230.251

Copper provides a more precise contrast than sapphire. The paper’s uncertainty budget gives sapphire-free autocollimator nonlinearity as 85.7 ppm, compared with 14.2 ppm in copper-free operation. Its pressure-correction contribution is 21.5 ppm in both sapphire modes and 1.6 ppm in copper. These differences motivate examining the copper configuration without discarding the sapphire results. [1]

How the printed values give the mode contrast

The normalized contrast is the free-deflection central value divided by the servo central value, minus one, multiplied by one million. Thus the denominator is the servo value. Normalizing instead to free deflection or to a combined constant would define a different statistic. Parts per million, abbreviated ppm, means a dimensionless ratio scaled by one million.

First-order propagation uses the derivatives of this ratio with respect to both inputs. In ppm units, multiply the free-to-servo ratio by the square root of the sum of the squared relative standard uncertainties minus twice their correlation times their product. The negative cross term retains cancellation of shared uncertainty in the difference. This is correlated-input propagation, not addition of independent error bars. [1] [10]

For copper the ratio uses 6.674021 divided by 6.673642. The relative uncertainties are 30.3 and 23.2 ppm, with correlation 0.42. The calculation gives a contrast of 56.7906 ppm and standard uncertainty 29.4269 ppm, rounding to 56.79 ± 29.43 ppm. Ignoring the correlation would give 38.16 ppm uncertainty instead.

For sapphire the corresponding ratio uses 6.673636 divided by 6.672637, relative uncertainties 93.9 and 37.5 ppm and correlation 0.25. The result rounds to 149.72 ± 92.01 ppm. Small differences in extra decimal places from earlier MQ summaries reflect use of printed rounded inputs, not a different experimental dataset. The reproduced values here are rounded calculations from those explicit inputs.

The fixed MQ target in current notation

Let 𝜃𝑠𝑖 be the dimensionless MQ invariant coefficient and 𝑛𝐿 the positive-real electromagnetic-demarcation length-count parameter. This calibrated continuation is distinct from primitive integer cardinality. Equation (1a) is the count constraint used for the current target. The central coefficient used in this illustration is 3.26239030504. [4] [7]

𝑛𝐿=276𝜃𝑠𝑖(1a)

Let 𝑄𝐿 denote the dimensionless Diophantine realization residual. Equation (2b) defines it for the positive count. The numerical evaluation uses the algebraically equal reciprocal of the sum of the root and the count to avoid subtractive cancellation. [7]

𝑄𝐿=1+𝑛𝐿2−𝑛𝐿(2b)

Here upright G denotes the upper-count gravitational coupling, while italic 𝐺 denotes the finite-count electromagnetic-demarcation coupling. Both have units m³ kg⁻¹ s⁻². The source relation is Equation (3c); typography distinguishes the realization regimes. [4] [7]

𝐺=2𝑄𝐿𝑛𝐿G(3c)

Dividing Equation (3c) gives the exact fractional separation in Equation (4d). Multiplying that dimensionless expression by one million produces the ppm target. Brief labels are separate from the source’s equation numbers.

G𝐺−1=12𝑄𝐿𝑛𝐿−1(4d)

The current calculation gives count 84.6005456716 and target 34.9284 ppm after displayed rounding. Associating free deflection with the upper-count regime and servo with the finite electromagnetic regime makes this a servo-normalized target. That apparatus assignment is additional physical interpretation; it is not proved by the count equations or by the presence of active electronics alone. [4]

These current digits describe the present calibrated construction. They do not show that the exact digits or the apparatus-specific assignment were preregistered before the experiment. The numerical realization history and the later apparatus identification must retain separate evidentiary roles. [4] [9]

Compatibility and departure from zero are different questions

Table 3 uses the current target as a fixed reference. A target pull is the contrast minus the target, divided by the contrast standard uncertainty. A zero pull divides the same contrast by its standard uncertainty. Only the primary experimental contrast budget is used; uncertainty in the physical validity of MQ’s mapping is not quantified by either pull.

Table 3: Calculated primary-budget contrasts and standardized differences
MaterialContrast (ppm)Standard uncertainty (ppm)Difference from MQ (standard uncertainties)Difference from zero (standard uncertainties)
Copper56.7929.430.7431.930
Sapphire149.7292.011.2481.627

Copper is 0.743 standard uncertainties above the fixed target and 1.930 above zero. Sapphire is 1.248 from the target and 1.627 from zero. Both central contrasts are positive, but neither excludes zero at two standard uncertainties under this budget. These statements are not posterior probabilities of competing physical causes.

Figure 2 shows one-standard-uncertainty intervals with the same normalization and values as Table 3. Such intervals must not be relabeled as 95% intervals. The two contrasts also remain correlated because their underlying measurements share entries in Table 2.

Figure 2. Reconstructed mode contrasts and one-standard-uncertainty intervalsCopper contrast 56.79 plus or minus 29.43 ppm. Sapphire 149.72 plus or minus 92.01 ppm. Fixed MQ target 34.9284 ppm and zero are marked. Intervals use primary-budget covariance and exclude the additional unidentified configuration effects in the final consensus model. The two material contrasts are not independent.Positive mode differences, with limited discrimination of the causeFree divided by servo, minus one · intervals show one standard uncertainty · primary budgets -60 0 60 120 180 240 280 Zero Fixed MQ Copper56.79 ± 29.43 ppm Sapphire149.72 ± 92.01 ppm Servo-normalized free-minus-servo contrast (ppm)Correlated configurations · fixed target is a theory reference, not an experimental best-fit value
Figure 2. Calculation from the rounded values and primary correlations in [1], Tables 16–18. The dashed MQ reference follows Equations (1a)–(4d). This is not a fit of an MQ mechanism to raw torque data.

What the primary contrast budget leaves out

The paper does not conclusively explain the mode offset. Its final consensus model allows unidentified configuration-specific biases in addition to the primary measurement uncertainties. The authors call these additional components dark uncertainty; the term concerns unexplained measurement variation and is unrelated to dark matter. Their combined estimate cannot be reconstructed by treating the primary contrasts as the whole uncertainty model. [1]

The 0.74-standard-uncertainty copper compatibility therefore has a defined scope. It includes the published primary systematic contributions and covariance, but not the additional bias terms used for the consensus. Using Type A uncertainty alone would be narrower still and would omit stated contributions. Neither procedure licenses an assumption that all unknown mode bias has been bounded.

The source authors regard instrumental systematics as more plausible than new physics in explaining the broader scatter of gravitational-constant measurements. The residual offset in this apparatus remains unresolved. The MQ account also warns against applying one extra universal rescaling to every laboratory length or to already realized electrical measurements. A valid physical explanation must follow the actual estimators without double-counting a calibration. [1] [4]

Chronology, authorship and a prospective test

The paper’s experimental data and primary analysis belong to Schlamminger and collaborators. Geiger’s subsequent calculation compares them with MQ. His reported nonparticipation in designing, conducting or analyzing the experimental campaign must not be confused with the absence of any earlier communication. The correspondence record separately distinguishes a broad earlier measurement-regime statement from a later apparatus-specific assignment. [4] [9]

A prospective test would fix the mode assignment, target, normalization and uncertainty procedure before inspecting new results. It would compare both zero separation and the specified MQ value, while controlling thermal, pressure, optical, electrical and mechanical effects. Better precision alone does not separate physics from an unrecognized mode-dependent bias; independent diagnostics and reversals are needed. [4] [8]

The covariance in Table 2 prevents treating copper and sapphire as independent discoveries. No new joint likelihood with historical BIPM campaigns is constructed here. A positive gap can remain compatible with several mechanisms, and compatibility with the target is not evidence that NIST endorsed MQ or that the proposed cause was isolated.

Source dates and reproducibility requests

April 16, 2026 is the experimental publication date. September 27, 2026 is the companion release’s recorded source-review snapshot. This Brief was prepared October 26, 2026. The current source notation and calibration digits are not assigned as historical apparatus predictions on those earlier dates.

For a reproducibility request, specify the four primary values, their relative budgets, all six correlations, denominator convention, rounding and the treatment of configuration-specific effects. For an experimental interpretation, request the torque and calibration diagnostics and the consensus-model assumptions. The calculations here reproduce the printed-input contrasts and current MQ target; they do not repeat the experiment, reprocess raw torque data or refit the full Bayesian consensus.

Research sources and further reading

  1. S. Schlamminger and collaborators, Redetermination of the gravitational constant with the BIPM torsion balance at NIST. Metrologia 63, 025012 (2026), DOI 10.1088/1681-7575/ae570f. Published April 16, 2026. Primary paper PDF. Tables 16–18 give the four mode results, primary uncertainty budgets and correlations; the following consensus analysis includes unidentified configuration effects. This paper controls over conflicting numerical publication metadata. Open source →
  2. NIST publication record for the same paper. Used for the institutional publication link and bibliographic context. The numerical result in its web abstract differs from the published paper; this Brief uses the paper’s 6.67387 ± 0.00038, multiplied by 10⁻¹¹ in SI gravitational units. Open source →
  3. S. Schlamminger, L. Chao, V. Lee, D. B. Newell and C. C. Speake, Design of electrostatic feedback for an experiment to measure G. Public author preprint arXiv:2206.04173, submitted June 8, 2022; DOI 10.1109/OJIM.2022.3182391. Describes free/Cavendish and electrostatic-servo operation. Open source →
  4. Informativity Institute, Gravitational Constant: MQ Derivation and Experimental Test. Current public account of the finite- and upper-count values, servo-normalized target and retrospective apparatus-mode assignment. MQ interpretation and statistical comparisons are distinct from the experimental collaboration’s conclusions. Open source →
  5. Informativity Institute, NIST–BIPM MQ Brief. Related public overview of the measurement configurations and numerical comparison. This new companion Brief reproduces the NIST-only contrasts from printed primary inputs and does not recompute a combined historical BIPM/NIST likelihood. Open source →
  6. Informativity Institute, Predictions of Measurement Quantization. Target normalization, chronology, source dependencies and prospective test requirements. Open source →
  7. J. A. Geiger, Distance Corresponding to the Length Contraction Associated with a Measure of Charge Couplings. Current public preprint. Supplies the count constraint and residual used for the present MQ numerical target; current calibration digits are not evidence of an apparatus-specific preregistration. Open source →
  8. Informativity Institute, planned measurement-mode experiment. Prospective research design and controls; it is not the NIST experiment and is not reported here as built, completed or independently validated. Open source →
  9. Informativity Institute, archived MQ measurement-mode correspondence release. Distinguishes earlier general communication from the later apparatus-specific interpretation and from evidence of receipt, influence or institutional endorsement. Open source →
  10. Joint Committee for Guides in Metrology, JCGM 100:2008, Evaluation of measurement data — Guide to the expression of uncertainty in measurement. Section 5.2 addresses correlated inputs. General metrology guidance, not an evaluation of MQ. Open source →

Prepared October 26, 2026. Reconstructed contrasts use printed primary budgets and covariance; additional consensus-bias terms are excluded. The MQ apparatus-mode assignment remains retrospective and no causal discovery or institutional endorsement is claimed.

Return to the press release